| AC WITHSTAND VOLTAGE |
| | Range | Resolution | Accuracy |
| Output Voltage, ACV | 0-5000 | 1 | ±(2% of setting+ 5V) |
| Output Frequency | 50Hz/60Hz ±0.1%, User Selection |
| Output Waveform | Sine Wave ,THD.<2% (Resistive Load), Crest Factor = 1.3 - 1.5 |
| Output Regulation | ± (1% of output + 5V), From no load to full load |
| SETTINGS |
| Maximum Limit current, mA | 0.000 - 9.999 (0=OFF) | 0.001 | ± (2% of setting + 2 counts) |
| 10.00-30.00 | 0.01 |
| Minimum Limit current, mA | 0.000 - 9.999 (0=OFF) | 0.001 | ± (2% of setting + 2 counts) |
| 10.00-30.00 | 0.01 |
| Ramp-Up Timer, second | 0.1 - 999.9 | 0.1 | ± (0.1% + 0.05 sec) |
| Ramp-Down Timer, second | 0.0 - 999.9 |
| Dwell Timer, second | 0, 0.4 - 999.9 (0=continuous) |
| Arc Detection | 1 - 9 ranges (9 is the most sensitivity) |
| DC WITHSTAND VOLTAGE |
| Output Voltage, DCV | 0-5000 | 1 | ±(2% of setting+ 5V) |
| Output Ripple | <4 %(5KV/10mA at Resistive Load) |
| SETTINGS |
| Maximum Limit, current, µA | 0 - 999.9 | 0.1 | ± (2% of setting + 2 counts) |
| 1000 - 10000 | 1 |
| Minimum Limit, current, µA | 0.0 - 999.9 | 0.1 | ± (2% of setting + 2 counts) |
| 1000 - 10000 | 1 |
| Ramp-Up Timer, second | 0.1 - 999.9 | 0.1 | ± (0.1% + 0.05 sec) |
| Ramp-Down Timer, second | 0, 1.0 - 999.9 (0=OFF) |
| Dwell Timer, second | 0, 0.4 - 999.9 (0=continuous) |
| Ramp-HI, current | >12 mA peak maximum, ON/OFF User Selection |
| Charge-LO, current | 0.0 - 350.0 µA DC or Auto Set |
| Discharge Time | ≦ 200 msec |
| Maximum Capacitive LoadDC Mode | 1 µF < 1KV 0.08 µF < 4KV |
| 0.75 µF < 2KV 0.04 µF < 5KV |
| 0.5 µF < 3KV |
| Arc Detection | 1 - 9 ranges (9 is the most sensitivity) |
| INSULATION RESISTANCE |
| Output Voltage, VDC | 50 - 1000 | 1 | ± (2% of setting + 2 counts) |
| Short Circuit Current | Maximum >12mA peak |
| SETTINGS |
Maximum and Minimun Limit Resistance, MΩ | 0.05 - 99.99(Max – Limit: 0 = OFF) | 0.01 | Same as Resistance MEASUREMENT Accuracy |
| 100.0-999.9 | 0.1 |
| 1000-50000 | 1 | ± (0.1% + 0.05 sec) |
| Ramp-Up Timer, second | 0.1 - 999.9 | 0.1 |
| Ramp-Down Timer, second | 0, 1.0 - 999.9 (0=OFF) |
| Delay Timer, second | 0, 1.0 - 999.9 (0=continuous) | 0.1 |
| Charge-LO, current, µA | 0.000 - 3.500 or Auto Set |
| MEASUREMENT |
| | Range | Resolution | Accuracy |
| Voltage, KV (AC/DC) | 0.00-5.00 | 0.01 | ± (1.5% of reading +2counts) |
| Voltage, Vdc (IR only) | 0-1000 | 1 | ± (1.5% of reading + 2counts) |
| AC Current, mA | 0.000-3.500 | 0.001 | ± (2% of reading + 2counts) |
| 3.00-30.00 | 0.01 |
| DC Current, µA | 0.0 - 350.0 | 0.1 | ± (2% of reading + 2 counts) |
| DC Current, mA | 0.300 - 3.500 | 0.001 |
| 3.00-9.99 | 0.01 |
| Resistance, MΩ | 50-499V | 500-1000V | 50 – 499V 0.05–999.9, ±(7% of reading+2 counts) |
| 0.050-1.999 | 0.050-9.999 | 0.001 | 500 – 1000V |
| 2.00-19.99 | 10.00-99.99 | 0.01 | 0.10–999.9, ±(2% of reading+2 counts) |
| 20.0-199.9 | 100.0-999.9 | 0.1 | 1000–9999, ±(5% of reading+2 counts) |
| 200-50000 | 1000-50000 | 1 | 10000–50000, ±(15%of reading+2 counts) |
| GENERAL |
| Input Voltage | 115/230Vac±15% Auto Selection, 50/60Hz ± 5%, Fuse 4A Slow-Blo 250VAC |
| PLC Remote Control | Input: Test, Reset, Interlock, Recall Memory 1 through 10 |
| Output: Pass, Fail, Test-in-Process, Reset Out |
| Remote Output Relays | 125VAC@1AAC, 30VDC@ 0.5ADC |
| Memory | 50 memories, 30 steps/memory |
| Graphic Display | 240 x 64 dot resolution Monographic LCD /Contrast 9 Levels 1-9 |
| Safety | Built-in Smart GFI circuit,GFI trip current 450µA max, HV shut down speed: <1mS |
| Interface | Standard RS232, Optional Printer Port,GPIB (IEEE-488.2),Multi-function Interface Card,Ethernet Card. |
| Security | Programmable password lockout capability to avoid unauthorized access to test set-up program. |
| Alarm Volume Setting | Range: 0-9 ;0=OFF, 1 is softest volume, 9 is loudest volume. |
| Calibration | Adjustments are made through the fornt panel. Built-in Verification program. |
| Automatic Calibration alert function to signal operator when calibration is due. |
| Environment | 0-40℃, 20-80%RH |
| Dimensions/Net Weight | (W × H × D) 2U (430 × 89 × 400 mm)/13Kg. |
| Option (Opt.735) | DC Continuity Test Function (0.1A/ 0-2KΩ) at Rear Panel |
| STANDARD ACCESSORIES |
| Power Cord(10A) | ×1 |
| Fuses | ×2 (Including a spare contained in the fuse holder) |
| Interlock Disable Key(1505) | ×1 |
| Hipot Test Lead ,1.5m(1101) | ×1 |
| Hipot Return Lead ,1.8m(1102) | ×1 |
| RS232 Link Cable 1.5m(1130) | ×1 |
| MATRIX SCANNER MODULE (Opt.729) |
| High Voltage Rating | 5KVAC/5KVDC |
| Number of HV Channel | 8 |
| MATRIX SCANNER MODULE (Opt.730) |
| High Voltage Rating | 5KVAC/5KVDC |
| Number of HV Channel | 4 |
| DC CONTINUITY TEST FUNCTION (Opt.735) |
| MEASUREMENT |
| | Range | Resolution | Accuracy |
| Output Current | DC 0.1A ± 0.01A, Max. |
| Resistance Display | 0.00 – 19.99 | 0.01 | ± (1 % of reading + 5 counts) |
| 20.0 – 199.9 | 0.1 | ± (1 % of reading + 2 counts) |
| 200 – 2000 | 1 | ± (1 % of reading + 2 counts) |
| SETTINGS |
| Max-Limit, Ω | 0.00 – 19.99 | 0.01 | ± (1 % of setting + 5 counts) |
| 20.0 – 199.9 | 0.1 | ± (1 % of setting + 2 counts) |
| 200 – 2000 | 1 | ± (1 % of setting + 2 counts) |
| Min-Limit, Ω | 0.00 – 19.99 | 0.01 | ± (1 % of setting + 5 counts) |
| 20.0 – 199.9 | 0.1 | ± (1 % of setting + 2 counts) |
| 200 – 2000 | 1 | ± (1 % of setting + 2 counts) |
| Dwell Timer, second | 0.0, 0.3 – 999.9 (0 = continuous) | 0.1 | ± (0.1% + 0.05 sec) |
| Resistance Offset, Ω | 0.00 – 2.00 | 0.01 | ± (1 % of reading + 5 counts) |